Distributed temperature sensing for geothermal boreholes and thermal response tests

What is the ground made of, layer by layer, and is the field slowly cooling?

The question

What is the ground made of, layer by layer, and is the field slowly cooling?

A conventional thermal response test gives one conductivity for the whole borehole. A fibre in the U-pipe gives one for every half metre, so the field is sized on the layers that are actually down there, and the same fibre keeps watching once the heat pumps run.

What you get
  • Thermal conductivity and borehole resistance per depth interval, with uncertainty, from one test.
  • Groundwater-affected intervals flagged where apparent conductivity rises with time.
  • For operating fields, the annual mean profile against the baseline year, drift in kelvin per year per depth, and an alarm when the field leaves its design envelope.
  • A report per test, and a dashboard for the years after.
What the fibre sees

The event, and the signal

  1. The rig pushes heat into the borehole. The fibre in the U-pipe reads every half metre.
  2. Layers that conduct well carry the heat away; layers that do not heat up more.
  3. The temperature rise per depth becomes conductivity per layer, from the same hours of heating.
What the site needs

Setup

FibreAny cable already in the U-pipe or grouted behind it, single-mode or multimode. No fibre yet? A slim borehole cable comes with the rental, terminated and cut to length.
Boreholes per instrumentUp to eight through the optical switch, so one box covers a test field.
Rig connectionThe test rig's energy meter, flow meter and inlet and outlet sensors plug into the same box, so the heat input and the response sit in one file on one clock.
PowerMains at the rig, or a battery and a panel for long-term monitoring at one profile an hour.
TermA campaign of two to four weeks per test, or continuous monitoring on a service contract.
How it works here

The measurement

During heating and recovery the temperature profile is recorded every few minutes. The late-time slope at each depth gives the conductivity of that interval by the line-source method, and a layered inversion with the known heat input refines it. Recovery is fitted as well as heating, so a shortened test still gives a result. For monitoring, each year's mean profile is compared with the first.

What lands on your desk

Deliverables

  • Conductivity versus depth with uncertainty band
  • Table per interval, conductivity, borehole resistance, advective flag
  • Monitoring dashboard with baseline and current profiles and the difference shaded
  • netCDF and CSV of every profile, for your own analysis

On the dashboard, through the API, and as files. All three, always.

Questions

Asked before

Can it replace the standard thermal response test?
It extends it. The same rig and heating schedule give the standard effective value and, from the same hours of heating, the depth-resolved profile on top.
How many boreholes can one instrument test at once?
Up to eight through the optical switch, sequentially within each profile. Fields are covered from one cabinet.
What if the borehole has no fibre?
A slim sensing cable is pushed into the U-pipe or taped to it before grouting. It comes with the rental, terminated and cut to length.

Put your fibre to work.

Tell us about your fibre and your question. You get a call, a plan for your site and a monthly price.